DYNAmas

The DYNAmas flowmeter is used for continuous flow measurement of all kinds of bulk materials by applying the capacitive measuring principle. Accurate online flow measurement in free fall, as well as for pneumatic transport systems.

Product concentration and transport speed are simultaneous and independently measured, and then used to calculate the mass flow rate. Thus, the measuring system is independent of fluctuating transport speeds.

The device, available in different nominal diameters, is easy to calibrate and its reduced dimensions allow hassle-free integration into existing systems.

Measures: Dust, Level, Moisture, Solids

DYNAmas_product-information_MAN-15-rev-2-en-GB (3)
Data Sheet

DYNAmas - for flow rates from 50 kg/h up to 400 t/h

  • contactless measuring
  • in free fall and for pneumatic transport systems
  • easy integration with existing systems
  • 10 sizes from DN25 to DN300 (ANSI 1"-12")
More info

The DYNAmas flowmeter is used for continuous flow measurement of all kinds of bulk materials by applying the capacitive measuring principle. Accurate online flow measurement in free fall, as well as for pneumatic transport systems.

Product concentration and transport speed are simultaneous and independently measured, and then used to calculate the mass flow rate. Thus, the measuring system is independent of fluctuating transport speeds.
The device, available in different nominal diameters, is easy to calibrate and its reduced dimensions allow hassle-free integration into existing systems.
In essence, DYNAmas contactless measuring is wear-free.

The DYNAmas flowmeter has been designed to handle any bulk material flow, starting already with small volumes. Accordingly, the device proves suitable for many different applications.
Configuration and measured values are displayed via the DYNAcon communication unit, which also provides various PLC interfaces.

Technical Specifications
Accuracy (typical)1 – 3 %
Process TemperatureStandard: max. 130 °C (266 °F)
Process PressureMax. 64 bar (900 lbs)
Ambient Temperature-40 °C … +60 °C (-40 °F … 140 °F)
Protection ClassIP 68 (EN 60529)
Interference ImmunityAccording to EN 61326-1
ParameterisationVia CAN-Bus through DYNAcon / Notebook
CAN-Bus OutputMass flow rate, concentration,
velocity, failure, simulation value,
limit status
CAN-Bus Transmission Rate40 kBaud, cable length max. 1000 m
Supply Voltage19 … 31 V DC, max. 10 W
Damping1 – 30 s, fast adaptation to rapid value changes

Why Choose Process Networks?

ISO-Certified Quality

Our ISO 9001:2015 quality management system ensures full traceability across design, installation, calibration and support.

Technical Expertise You Can Reach

When you contact us, you speak directly to an expert — not a call centre.

Trusted Supplier Partnerships

Exclusive access to premium instrumentation from leading global manufacturers in Germany, Japan, the US and across Europe.

Long-Term Support & SLAs

Most customers stay with us for years because we stay with them providing ongoing maintenance, calibration and on-site service.

Proven Field Experience

Thousands of instruments installed and tens of thousands points monitored daily on systems we support.

Speak to a technical expert about this product

Our experts will guide you to the right solution whether you need a single sensor or a site-wide monitoring system.

Office

Process Networks Ltd,
Unit K20 Drinan Enterprise Centre,
Swords, Co. Dublin, K67 NN59

Call

(01) 211 8414

Email

info@processnetworks.ie

    By submitting your enquiry, you agree to receive updates from Process Networks in accordance with our Privacy Policy.