E490 Explosion proof – Multi-Purpose Indicator

The E490 is a versatile, loop powered multi-purpose indicator to display the actual process value, range and loop current. Besides the focus on level, temperature and pressure applications, the E490 can also work with other measuring units, like %, mA, RPM and even the possibility to create a custom unit with max. 8 characters.

E490-DATA-EN-V2604
Datasheet

Measure. Monitor. Repeat.

For better insights, better decision-making and better process performance.

Key Features & Benefits

  • Explosion proof according ATEX, IECEx and CSA C-US.
  • Universal loop powered indicator.
  • Input signal: Galvanically isolated 4 – 20mA with ultra low voltage drop < 1.5V DC, allowing easy installation in almost any 2-wire, 4–20mA loop.
  • Create a custom measuring unit with max. 8 characters.
  • Aluminum or high grade stainless steel Ex d enclosure.
  • Easy installation with the spacious chamber and plug & play connectors.
  • Key information at a glance as the display shows the actual value, measuring unit and loop current and a 10 segments bargraph.
  • 5 Large 17.3mm (0.7”) digits.
  • Selectable engineering units for many different applications: L- NL- mL – M3- AM3- NM3 – mg – g – Kg – TON- OZ- GAL – USGAL – IGAL – lb – bbL- cf – CUFt – scf – p – rev – °C – °F – K – % – M – mm – CM – mtr – inch – Ft – SQFt – Yd – PSI – psig – mbar – MbARG – bar – barg – bara – PA – PAG – KPA – KPAG – MPA – INHG – mmHg – mmH2O – MH2O – INH2O- Ph – mV – mA – A – uS – PPM – RPM – custom unit or no unit.
  • LED backlight circuit which can be powered from the loop (voltage drop 6.5V DC), it is separated from the input circuit.
  • Auto backup of all settings.
  • Ambient temperature aluminum enclosure: -40°C to +70°C (-40°F to 158°F).
    Ambient temperature stainless steel enclosure: -40°C to +67°C (-40°F to 153°F).
  • Various accessories are available for this product.

Typical Applications

  • Universal applications when a local loop-powered multi-purpose display is required without monitoring function, linearization or signal re-transmitting.
  • The E490 takes operating energy from an input current (2-wire 4 – 20mA) and has a separated backlight circuit which can be powered from the loop.
  • The E-Series can be used in rough and tough applications, beyond being just explosion proof. Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market! The E-Series is always your first and safest choice in explosion proof applications.

Advantages

  • Saves time and improves flexibility with the through-glass keypad: no need to open the front cover.
  • Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
  • Durable high-grade stainless steel 316L Ex d enclosure withstanding extreme (maritime) conditions.
Signal, Power and Communication Specifications
Signal InputsMulti-Purpose Input:
Galvanically isolated 4–20 mA input, loop-powered
Ultra-low voltage drop < 1.5 V DC
Alarm OutputsNone
Analog OutputsNone
Power Supply4–20 mA input loop-powered (loop can power the backlight)
Optional external supply: 9 – 27 V DC
When externally powered, the backlight operates at full intensity
and does not influence loop voltage drop
Sensor SupplyNone
Hazardous AreaIntrinsically Safe
For intrinsically safe applications, F-Series instruments are recommended
Explosion Proof ApprovalsATEX:
Gas: II 2 G Ex db IIC T6 Gb
Dust: II 2 D Ex tb IIIC T85°C DbIECEx:
Gas: Ex db IIC T6 Gb
Dust: Ex tb IIIC T85°C DbCSA C-US:
XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D
DIP (Dust-Ignition-proof): Class II, Div. 1, Groups E, F & G T85°C; Class III
Gas: Class I, Zone 1, AEx db IIC T6 Gb
Dust: Zone 21, AEx tb IIIC T85°C Db
CommunicationModbus communication available on F1-Series products
HART communication available with the E018 Flow Rate Monitor / Totalizer
Alternative ProductsF490: Safe area / intrinsically safe, loop-powered multi-purpose indicator
D490: DIN panel mount & intrinsically safe, loop-powered multi-purpose indicator

Quickstart Guide Quickstart Remote Conf Tool-V3.4 (2)
Declaration of ConformityDeclaration of Conformity E-Series 2023-01 EU (2)
Battery Information SheetMSDS Battery-Information-Sheet (7)

Why Choose Process Networks?

ISO-Certified Quality

Our ISO 9001:2015 quality management system ensures full traceability across design, installation, calibration and support.

Technical Expertise You Can Reach

When you contact us, you speak directly to an expert — not a call centre.

Trusted Supplier Partnerships

Exclusive access to premium instrumentation from leading global manufacturers in Germany, Japan, the US and across Europe.

Long-Term Support & SLAs

Most customers stay with us for years because we stay with them providing ongoing maintenance, calibration and on-site service.

Proven Field Experience

Thousands of instruments installed and tens of thousands points monitored daily on systems we support.

Speak to a technical expert about this product

Our experts will guide you to the right solution whether you need a single sensor or a site-wide monitoring system.

Office

Process Networks Ltd,
Unit K20 Drinan Enterprise Centre,
Swords, Co. Dublin, K67 NN59

Call

(01) 211 8414

Email

info@processnetworks.ie

    By submitting your enquiry, you agree to receive updates from Process Networks in accordance with our Privacy Policy.