F126-EL Safe area / Intrinsically safe – Flow Computer for liquids
The F126-EL flow computer has been developed to calculate corrected liquid volume at normal conditions. The corrected volumetric flow is calculated by measuring the uncorrected volumetric flow and actual line temperature which is processed with the thermal expansion coefficient algorithm stored in the flow computer. The reference temperature can be defined as desired (e.g. 15°C, 20°C or 60°F).
Measure. Monitor. Repeat.
For better insights, better decision-making and better process performance.
Key Features & Benefits
- Calculates compensated flow rate, total and accumulated total based on a temperature/expansion relationship.
- Displays actual line temperature.
- Analog output signal reflecting the corrected flow rate.
- Displays total and flow rate simultaneously and additional accumulated total.
- Flow rate: seven 8mm (0.31″) digits.
- Total – resettable: seven 17mm (0.67″) digits.
- Accumulated total – not resettable: eleven 8mm (0.31″) digits.
- Temperature: six 17mm (0.67″) digits.
- Engineering units for flow rate, total and temperature on the display.
- LED backlight.
- Intrinsically safe according ATEX and IECEx.
- GRP, Aluminum or high grade stainless steel enclosure.
- Auto backup of settings and running totals in EEPROM memory.
- Ambient temperature: -40°C to +70°C (-40°F to 158°F).
Typical Applications
- Liquid flow measurement in applications where nett flow calculation at base conditions is desired without the influence of thermal product expansion.
- The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +70°C (-40°F up to 158°F).
Advantages
- Robust aluminum or stainless steel 316L field enclosure (IP65, IP67 / NEMA Type4X) .
It is so rugged, a truck can even stand on it! - Intrinsically Safe available - ATEX and IECEx approval for gas and dust applications.
- Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
- Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.
| Category | Function / Description | Type / Details |
|---|---|---|
| Signal Inputs | Flowmeter Inputs | Pulse type inputs: Reed-switch, open collector, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. |
| Temperature Inputs | PT100 – 2-wire or 3-wire PRTD sensor | |
| Signal Outputs | Pulse Outputs | Scaled pulse output according to accumulated total (e.g. a pulse every 3.25 gallons). Max. frequency: 500Hz. Adjustable pulse length: 0.001 sec to 9.999 sec. Type: One passive NPN transistor, active PNP transistor, or isolated electro-mechanical relay. |
| Alarm Outputs | None | |
| Analog Outputs | Re-transmitting the compensated flow rate, scalable to any range (e.g. 200 L/min to 1200 L/min). One passive isolated, floating or loop-powered 4–20mA output, or one active (0)4–20mA / 0–10V DC output. | |
| Supply | Power Supply | Long life Lithium battery. 4–20mA loop-powered. 8–24V AC/DC. 115–230V AC. Basic: 8–30V DC |
| Sensor Supply | 3.2V, 8.2V, 12V, 24V DC | |
| Hazardous Area – Intrinsically Safe | ATEX: Gas: II 1 G Ex ia IIB/IIC T4 Ga Dust: II 1 D Ex ia IIIC T200 100 °C Da IECEx: Gas: Ex ia IIC/IIB T4 Ga Dust: Ex ia IIIC T200 100 °C Da | |
| Explosion Proof | ATEX/IECEx: Gas: II 2 G Ex db IIB+H2 T5 Gb Dust: II 2 D Ex tb IIIC T80 °C Db | |
| Communication | All process data and settings can be read and modified through the communication link. Protocol: Modbus RTU. Interface: RS232 / RS485 2-wire or 4-wire / TTL. HART communication available with the F018 Flow rate Monitor / Totalizer. | |
Why Choose Process Networks?

ISO-Certified Quality
Our ISO 9001:2015 quality management system ensures full traceability across design, installation, calibration and support.

Technical Expertise You Can Reach
When you contact us, you speak directly to an expert — not a call centre.

Trusted Supplier Partnerships
Exclusive access to premium instrumentation from leading global manufacturers in Germany, Japan, the US and across Europe.

Long-Term Support & SLAs
Most customers stay with us for years because we stay with them providing ongoing maintenance, calibration and on-site service.

Proven Field Experience
Thousands of instruments installed and tens of thousands points monitored daily on systems we support.









Speak to a technical expert about this product
Our experts will guide you to the right solution whether you need a single sensor or a site-wide monitoring system.
Office
Process Networks Ltd,
Unit K20 Drinan Enterprise Centre,
Swords, Co. Dublin, K67 NN59
Call
(01) 211 8414
info@processnetworks.ie