B-Alert Basic – Flow rate Monitor / Totalizer
The B-Alert is a flow rate indicator / totalizer with continuous flow rate monitoring feature. It has one low flow rate and one high flow rate alarm value. The display shows flow rate, total, accumulated total and alarm messages. On-screen engineering units are easily configured from a comprehensive selection.
Measure. Monitor. Repeat.
For better insights, better decision-making and better process performance.
Key Features & Benefits
- Compact design.
- Displays instantaneous flow rate, total, accumulated total and alarm messages.
- Two alarm values can be entered: low and high flow rate alarm.
- Durable IP65 (Type 4X) field, wall or meter mount enclosure.
- One 20mm (0.79″) and two 16mm(0.63″) knock-out hole cable entries.
- “Know one, know them all” configuration structure.
- Easy reading and programming with clear alphanumerical display.
- Clear 12mm(0.5”) numeric digits and 7mm(0.3”) alphanumeric digits.
- Bright LED backlight.

Typical Applications
- Basic flow rate monitoring with a precise calculation over the full measurement range, where re-transmission of the totalizer and monitoring of the flow rate function is required.
- The B-series offers you an economical solution for common industrial applications. Nothing more, nothing less.
Advantages
- Basic flow rate monitoring with a precise calculation over the full measurement range, where re-transmission of the totalizer and monitoring of the flow rate function is required.
- The B-Series is our most cost effective display but with all the benefits you may expect from a Fluidwell product: It’s durable, reliable and very easy to operate. Basic with a capital B!
- Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
| Technical Data – Flow Rate Monitor | |
|---|---|
| Signal Inputs – Flowmeter Inputs | Namur; Reed-switch; NPN; PNP; Sine wave (coil) |
| Signal Outputs – Pulse Outputs | Function: Two configurable pulse outputs according to accumulated total (e.g. one pulse every 3.25 gallons) Frequency: User selectable: Off; Long (5 Hz / 100 ms); Intermediate (33 Hz / 15 ms); Short (100 Hz / 5 ms) Type: Two passive transistor outputs (NPN), not isolated |
| Signal Outputs – Alarm Outputs | Function: Two configurable alarm outputs for low or high flow rate alarms Type: Two passive transistor outputs (NPN), not isolated |
| Signal Outputs – Analog Outputs | None |
| Signal Outputs – Control Outputs | None |
| Power Supply | Single 3.6 V lithium AA battery; 10 – 30 V DC |
| Sensor Supply | 8.2 V DC |
| Intrinsically Safe | For Intrinsically Safe applications, the F-Series is recommended |
| Explosion Proof | For Explosion Proof applications, the E-Series is recommended |
| Communication | Modbus communication available on the F113 Flow Rate Monitor; HART communication available with the F018 Flow Rate Monitor / Totalizer |
Why Choose Process Networks?

ISO-Certified Quality
Our ISO 9001:2015 quality management system ensures full traceability across design, installation, calibration and support.

Technical Expertise You Can Reach
When you contact us, you speak directly to an expert — not a call centre.

Trusted Supplier Partnerships
Exclusive access to premium instrumentation from leading global manufacturers in Germany, Japan, the US and across Europe.

Long-Term Support & SLAs
Most customers stay with us for years because we stay with them providing ongoing maintenance, calibration and on-site service.

Proven Field Experience
Thousands of instruments installed and tens of thousands points monitored daily on systems we support.









Speak to a technical expert about this product
Our experts will guide you to the right solution whether you need a single sensor or a site-wide monitoring system.
Office
Process Networks Ltd,
Unit K20 Drinan Enterprise Centre,
Swords, Co. Dublin, K67 NN59
Call
(01) 211 8414
info@processnetworks.ie