CS2 Correlation Pipe Sensor

The pipe sensors are designed for mounting from the outside into the pipelines using nozzles.

In combination with transmitters such as NivuFlow 750 or NivuFlow 7550 and an additional external level measurement, they form a complete flow measurement system for part filled applications. They can also be used for permanently full pipes or Channels. The additional height measurement can be omitted here.

Measures: Flow

S-AS_TB_Rev12_en (3)
Technical Instruction

Measure. Monitor. Repeat.

For better insights, better decision-making and better process performance.

Key Features & Benefits

  • Very high accuracy by means of ultrasonic cross correlation method
  • Interference-free connection over long distances through digital signal transmission
  • Cable extensions over several 100 metres with standard cables possible without any problems
  • Absolutely stable zero point and drift-free
  • Measurement in slightly to heavily contaminated media
  • Suitable for media with high solids loads
  • Easy installation without additional constructions thanks to optimised mounting accessories
  • Installation under process conditions possible
  • Particularly suitable for pipe sections starting at 1000 mm diameter

Typical applications for CS2 pipe sensor

  • Channel networks: billing measurement places, flow measurement in large pipe sections
  • Wastewater treatment plants: intake, discharge, activated sludge tank intakes, return sludge, recirculation, surplus sludge, digester discharge and flocculant dosage
  • Pump stations: pumped quantities
  • Industrial wastewater networks
  • and many more

Large measurement range for big pipes

Ultrasonic sensors for flow measurement with very high accuracy in slight to heavily polluted media. For installation in pipes up to 5000 mm diameter

More info

The pipe sensors are designed for mounting from the outside into the pipelines using nozzles. In combination with transmitters such as NivuFlow 750 or NivuFlow 7550 and an additional external level measurement, they form a complete flow measurement system for part filled applications. They can also be used for permanently full pipes or Channels. The additional height measurement can be omitted here.

Technical Data – Ultrasonic Flow Velocity Sensor
Measurement principleCorrelation with digital pattern recognition (Flow Velocity)
Measurement frequency1 MHz
ProtectionIP 68
Ex-ApprovalII 2 G Ex ib IIB T4 Gb (ATEX)
Ex ib IIB T4 Gb (IECEx)
Operating temperature−20 °C to +50 °C
−20 °C to +40 °C for Ex Zone 1
Storage temperature−30 °C to +70 °C
Operating pressureMax. 4 bar (for combi sensors with pressure measuring cell max. 1 bar)
Cable lengths Sensors without plugs (type “K” and “L”): extendable to max. 250 m
Pressure measurement cell (Type VxD0/VxU1): pressure compensation required for cable lengths over 30 m
Cable typesLiYC11Y 2 x 1.5 + 1 x 2 x 0.34
Outside diameter: 8.4 mm ±0.25 mm
Sensor typesFlow velocity sensor with v-measurement by cross-correlation and temperature compensation
ConstructionPipe sensor with sensor screw joint and retaining element
Medium-contacting materialsPolyurethane, stainless steel 1.4571, PPO GF30, PEEK, PA6
Measurement range−350 cm/s to +600 cm/s
Max. measuring spanΔ 700 cm/s
Quantity of scan layers recordedMax. 32
Zero point driftAbsolutely stable zero point
Error limits (per scan layer) < 1 % of measurement value (v > 1 m/s)
< 0.5 % of measurement value + 5 mm/s (v < 1 m/s)

Technical Instructions S-AS_TB_Rev12_en (3)
Mounting Instruction KK-Doppler_MA_Rev08_en (3)
EU Type examination certificate Aktivsensoren-POA-OCL-CS2_TUEV_03_ATEX_2262_X__issue__00_THN (3)
IECEx Certificate of ConformityAktivsensoren-POA-OCL-CS2_IECEx_TUN_15.0014_002_THN (3)

Why Choose Process Networks?

ISO-Certified Quality

Our ISO 9001:2015 quality management system ensures full traceability across design, installation, calibration and support.

Technical Expertise You Can Reach

When you contact us, you speak directly to an expert — not a call centre.

Trusted Supplier Partnerships

Exclusive access to premium instrumentation from leading global manufacturers in Germany, Japan, the US and across Europe.

Long-Term Support & SLAs

Most customers stay with us for years because we stay with them providing ongoing maintenance, calibration and on-site service.

Proven Field Experience

Thousands of instruments installed and tens of thousands points monitored daily on systems we support.

Speak to a technical expert about this product

Our experts will guide you to the right solution whether you need a single sensor or a site-wide monitoring system.

Office

Process Networks Ltd,
Unit K20 Drinan Enterprise Centre,
Swords, Co. Dublin, K67 NN59

Call

(01) 211 8414

Email

info@processnetworks.ie

    By submitting your enquiry, you agree to receive updates from Process Networks in accordance with our Privacy Policy.