HVT 300-DX
Typically, the voltage transmitter is used in applications in which safety measures must be switched safely depending on a certain voltage threshold (for example 50 V). This can be e.g. controlling the access to an automotive test bed with high powertrain voltages >800 V.
Measure. Monitor. Repeat.
For better insights, better decision-making and better process performance.
Key Features & Benefits
- Failsafe voltage monitoring
- Simple software configuration via USB or Modbus RTU
- 0-1000V DC measurement range
- Redundant architecture
- Robust design with high dielectric strength
- SIL2 according to IEC/EN 61508
- Two individual safety outputs
- LED status: Power, Error, Alarm
- 10-year proof test interval

Typical Applications
- Automotive high-voltage test benches
- Electric vehicle powertrain and battery testing
- Access control systems for high-voltage work areas
- Simulation of high-voltage powertrain components
- Manufacturing and end-of-line testing of EV components
- High-voltage systems in electrified industrial applications
Scope of use
- Battery
- Battery Management System
- Motor
- Inverter
- Climate Aggregate
- Charger
- Compressor
- HV-Supply
Safety Features
Featuring a safety-by-design approach, the HVT 300-DX provides a wide range of diagnostic functions. In order to create a safety loop, the desired output must be evaluated in conjunction with one of the two diagnostic relays REL3/REL4. This way, two individually configurable safety outputs can be created, for which either the relays REL1/REL2 or the 4…20mA analog output are available.
| Category | Parameter | Specification |
|---|---|---|
| Certification | Functional Safety | SIL 2 according to IEC 61508 |
| Measurement Range | 0 … 1000 V DC | |
| Input Resistance | 12 MΩ per channel | |
| Analog Output | Output Range | 0 / 4 … 20 mA |
| Load | Max. 500 Ω at 22 mA | |
| Accuracy | < 0.5 % | |
| Contact Outputs | Contact Type | Normally Open (NO) |
| Contact Material | AgPd + 10 µAu | |
| Switching Power | Max. 62.5 VA / Max. 30 W | |
| Switching Voltage | Max. 125 VAC / 110 VDC | |
| Switching Current | Max. 1 A | |
| Status LEDs | Power | Green |
| Error / SIL Alarm | Red | |
| REL1 / REL2 | Yellow | |
| Indication | Device and relay status | |
| Interfaces | USB Interface | USB 2.0 |
| RS485 Interface | Baud rate: 9600 bps Device address: 1 … 248 Communication: Half duplex, no scheduling | |
| Power Supply | Supply Voltage | 24 VDC (20 … 30 VDC) |
| Power Consumption | Max. 1.9 W | |
| Environmental Conditions | Operating Temperature | -10 °C … +60 °C |
| Storage / Transport Temperature | -20 °C … +70 °C | |
| Permissible Humidity | 10 % … 90 % r.H., non-condensing | |
| Max. Operating Altitude | < 2000 m above mean sea level | |
| Temperature Coefficient | < 0.01 %/K (max) < 0.005 %/K (typical) | |
| Electrical Safety | Galvanic Isolation | 4.3 kV AC test voltage |
| Overvoltage Category | CAT II: 1000 V | |
| Pollution Degree | 2 | |
| Mechanical Data | PCB Material | FR4 |
| Housing Material | Polyamide | |
| Protection Class | IP20 | |
| Flammability / Mounting | UL94 V0 / 35 mm DIN rail |
Why Choose Process Networks?

ISO-Certified Quality
Our ISO 9001:2015 quality management system ensures full traceability across design, installation, calibration and support.

Technical Expertise You Can Reach
When you contact us, you speak directly to an expert — not a call centre.

Trusted Supplier Partnerships
Exclusive access to premium instrumentation from leading global manufacturers in Germany, Japan, the US and across Europe.

Long-Term Support & SLAs
Most customers stay with us for years because we stay with them providing ongoing maintenance, calibration and on-site service.

Proven Field Experience
Thousands of instruments installed and tens of thousands points monitored daily on systems we support.









Speak to a technical expert about this product
Our experts will guide you to the right solution whether you need a single sensor or a site-wide monitoring system.
Office
Process Networks Ltd,
Unit K20 Drinan Enterprise Centre,
Swords, Co. Dublin, K67 NN59
Call
(01) 211 8414
info@processnetworks.ie