HVT 400-DX

The HVT 400-DX is a SIL2-compliant voltage monitoring transmitter designed for safe and reliable monitoring of high-voltage systems. It enables automatic triggering of safety measures based on configurable voltage thresholds, making it ideal for controlling access to test beds, simulating high-voltage powertrain components, and ensuring safe operation of electrification systems across automotive and industrial applications.

Brochure-HVT400_EN (1)
Brochure

Measure. Monitor. Repeat.

For better insights, better decision-making and better process performance.

Key Features & Benefits

  • Failsafe voltage monitoring
  • Simple software configuration via USB or Modbus
  • 0-1500V AC/DC measurement range
  • Redundant architecture
  • Robust design with high dielectric strength
  • SIL2 according to IEC/EN 61508
  • Two individual safety outputs
  • LED status: Power, Error, Alarm
  • 10-year proof test interval

HVT 400-DX

Typical Applications

  • Controlling access to automotive test beds
  • Simulation of high-voltage powertrain components
  • Triggering safety measures based on voltage thresholds
  • Use in electrification components across various industries

Safety Features

Featuring a safety-by-design approach, the HVT 400-DX provides a wide range of diagnostic functions. In order to create a safety loop, the desired output must be evaluated in conjunction with one of the two diagnostic relays REL3/REL4. This way, two individually configurable safety outputs can be created, for which either the relays REL1/REL2 or the 4…20mA analog output are available.

More info

Scope of use

  • Battery
  • Battery Management System
  • Motor
  • Inverter
  • Climate Aggregate
  • Charger
  • Compressor
  • HV-Supply

 

ParameterSpecification
CertificateSIL 2 according to IEC 61508
Measurement range0–1500 V AC/DC
Overrange1800 V (permanent)
Input resistance12 MΩ
Analog Output0–22 mA / 22–0 mA
Analog LoadMax. 500 Ω at 22 mA
Accuracy< 0.005%
Contact outputsSwitching Power: Max. 62.5 VA / Max. 30 W
Switching Voltage: Max. 125 VAC / 110 VDC
Switching Current: Max. 1 A
Contact Material: Ag Pd + 10 µAu
Normally Open
Status LEDsPower: Green
Error / SIL Alarm: Red
REL1 / REL2: Yellow
USB InterfaceFront socket USB 2.0
RS485 InterfaceBaud rate: 9600 bps, Device Address: 1–248, Half duplex, no scheduling
Supply24 VDC (20–30 VDC)
Power ConsumptionMax. 1.9 W
TemperatureOperating: -10°C…+60°C, Storage/Transport: -20°C…+70°C
Permissible Humidity10%…90% r.H, no condensation
Max. Operating Altitude< 2000 m above mean sea level
Temperature CoefficientMax: <0.01%/K, Typical: <0.005%/K
Galvanic isolation / Overvoltage category4.3 kV AC test voltage, CAT II: 1500 V, Pollution Level 1
PCB MaterialFR4
Housing MaterialPolyamide
Protection ClassIP20
FlammabilityUL94 V0
Mounting type35 mm DIN rail

Datasheet647_HVT400DXManualEN-1

Why Choose Process Networks?

ISO-Certified Quality

Our ISO 9001:2015 quality management system ensures full traceability across design, installation, calibration and support.

Technical Expertise You Can Reach

When you contact us, you speak directly to an expert — not a call centre.

Trusted Supplier Partnerships

Exclusive access to premium instrumentation from leading global manufacturers in Germany, Japan, the US and across Europe.

Long-Term Support & SLAs

Most customers stay with us for years because we stay with them providing ongoing maintenance, calibration and on-site service.

Proven Field Experience

Thousands of instruments installed and tens of thousands points monitored daily on systems we support.

Speak to a technical expert about this product

Our experts will guide you to the right solution whether you need a single sensor or a site-wide monitoring system.

Office

Process Networks Ltd,
Unit K20 Drinan Enterprise Centre,
Swords, Co. Dublin, K67 NN59

Call

(01) 211 8414

Email

info@processnetworks.ie

    By submitting your enquiry, you agree to receive updates from Process Networks in accordance with our Privacy Policy.