NIVUFLOW 750
Precise and reliable flow measurement across a wide range of applications.
The NivuFlow 750 is a high-performance universal transmitter designed for precise and reliable flow measurement across a wide range of applications. Engineered for flexibility and accuracy, it supports multiple sensor types and measurement methods, making it an ideal solution for complex flow monitoring requirements.
Its robust design and advanced signal processing ensure dependable performance even in challenging environments.
Measure. Monitor. Repeat.
For better insights, better decision-making and better process performance.
Key features & benefits:
- Universal transmitter compatible with various flow sensors and measurement principles
- High measurement accuracy with advanced signal processing
- Suitable for open channel and partially filled pipe applications
- Flexible integration with existing monitoring and control systems
- Clear, user-friendly interface for easy setup and operation
- Robust, industrial-grade design for long-term reliability
- Ideal for water, wastewater, and industrial flow monitoring applications
Typical Applications
- WWTPs
- channel networks
- discharge constructions
- industrial wastewater networks
- measurement places for billing
- intakes
- drainage lines
- return sludge lines
- recirculation lines
- and many more
Flow measurement with cross correlation technology
For ultrasonic flow measurement of slight to heavily polluted media in part filled and full pipes and channels. Best possible results even under difficult conditions.
More info
Flow measurement systems at the highest technical level
- Very high accuracy flow meter by means of ultrasonic cross correlation method
- Also suitable for the most difficult applications
- Measurement of the real flow velocity profile
- Up to 32 individual velocities per sensor
- Integrated, scientifically developed flow models
- Worldwide connectivity for commissioning, maintenance, data transfer and service
- Extensive diagnostic functions for safe and fast commissioning and maintenance
- Self-monitoring and self-diagnosis with status output in accordance with Namur NE 107
- Cycle operation for autonomous measurements
- Combination of several partial measurement points with different measurement methods in one overall measurement
Innovation, reliability and maximum accuracy
Together with the sensors, the NivuFlow 750 forms a stationary measuring system for continuous flow measurement and flow control for low to heavily contaminated media of various compositions.
It is used in part filled and full flumes, canals and pipes of various geometries and dimensions. The measurement transducer is able to record the current flow rate at a maximum of 3 different measuring points with up to 81 flow velocity sensors.


The right sensor for each application
A wide selection of sensor designs is available for measuring flow velocity and flow level in flumes, pipes and canals ranging from very small to several metres in size: Flow velocity sensors with and without integrated flow level measurement as well as air-ultrasonic flow level sensors.
Highly resistant sensors in PEEK design with Hastelloy mounting plates or in titanium design and FEP-protected cables withstand even highly aggressive and corrosive environments.
Your benefits
- Absolutely zero point stable and drift-free sensors
- Low installation expenses through perfectly matched mounting accessories
- Installation under process conditions
- Various sensor constructions guarantee the best solution for each application
- Digital signal transmission for errorfree connections over long distances
- Ex approval Zone 1


Application Examples
- Pump Stations
- Quick and easy retrofitting to all pipework materials
- No cutting or dismantling of existing pipes
- Reliable and accurate measurement of slightly polluted media through to to sludge
Control Measurement Section
- Measurement and control of transfer volumes in rainwater treatment plants
- Reliable and accurate recording of night-time discharges, dry and rainwater volumes
- Intelligent control algorithms for surge detection, quick close and flush-free as well as automatic flushing functions
- Easy integration into higher-level sewer management systems
Measurement Places for Billing
- Equipment for calibrated and certified billing measuring points, e.g. for industrial dischargers
- Highly accurate multi-path systems with up to 288 precisely positioned individual flow velocities in the flow profile
- Absolutely zero-point stable and drift-free measuring system without interference from sieve skins, grease films, etc.
Multi Measurement Places
- Combination of different measuring methods at complex measurement places
- Multiple measuring point capability
- Integration option for up to 81 flow velocity measurement sensors
- Modbus coupling of all NivuFlow transmitters




Nivu Flow 750 - Universal transmitter
The intuitive one-hand operation and the bright high-resolution colour display allow quick, easy and cost-efficient commissioning on site. Additional input devices or software are not required. The latest integrated numeric discharge models enable more accurate, more stable and more reliable determination of flow rates even under very difficult measurement conditions.
The 3D flow profile is calculated in real time and is reproducibly and verifiably indicated on the transmitter display. Factors influencing the calculation results such as channel shapes, discharge behaviour and wall roughness are considered during flow calculation.
Delayed discharge behaviour and variable backwater effects are reliably recorded and taken into account in the calculation. In addition to the compact DIN rail version there is a weatherproof field unit available featuring appropriate connection space for outdoor installation.

Sensor Monitoring and Self Diagnostics
An integrated, fully automatic evaluation algorithm allows a continuous check for any maintenance requirements or a necessary check of the measurement system.
A Namur NE 107-compliant diagnosis and status evaluation informs the operator about maintenance requirements, wear, sensor damage or destruction, as well as spillage or silting up of the measurement point. The sensor states classified in accordance with the Namur NE 107 protocol are shown on the graphic display using a colour-coded display and Namur-defined symbols. They can be transmitted via Modbus, integrated modem and alarm management system as well as via error message outputs.
Sensor in working order
- Functionally reliable measurement within the specification

Maintenance required
- Unspecific sensor behaviour (incrustations, disturbances in front of the sensor)
- Measurement works, but should be checked

Sensor outside the specification
- Wear/spillage
- Sensor damage
- Impending measurement failure

Sensor not in working order
- Mechanical sensor damage
- Electronic damage
- Massive wear
- Sensor destruction

IoT-Ready Flow Measurement
- Integrated data logger for high data security and large storage capacity
- Stored data can be read out at any time using integrated, global connectivity
- Online operation and online parameterisation (remote control)
- Quick and comprehensive remote diagnosis of the entire measuring point

| Technical Data – Common | |
|---|---|
| Power supply | 100…240 V AC, -15 % / +10 %, 47…63 Hz or 10…35 V DC |
| Power supply connection | AC: Plugged and screwed spring-cage terminal block DC/DL: Plugged spring-cage terminal block |
| Maximum power consumption | AC: 30 VA DC: 20 W |
| Typical power consumption | Configuration: 1× POA-VxU1 + 1× i-Sensor + 1 relay energised + 1× iXT 230 V AC: 14 VA / 6.8 W 24 V DC: 6.2 W |
| Enclosure | |
| DIN Rail enclosure | Material: Aluminium and plastic Weight: approx. 1300 g |
| Field enclosure | Material: Polyamide PA / Polycarbonate PC Weight: approx. 4000 g (incl. NF750 and iXT0 211) |
| Protection | |
| DIN Rail | IP20 |
| Field enclosure | IP67 (option IP68) |
| Operating Conditions | |
| Protection class | Class I |
| Overvoltage category | II |
| Pollution degree | 2 |
| Operating altitude | AC unit: up to 3000 m above MSL Relay voltages >150 V: max. 2000 m above MSL (AC and DC) |
| Operating temperature | DC: -20…+70 °C AC: -20…+65 °C |
| Storage temperature | -30 °C … +80 °C |
| Max. ambient temperature | +50 °C |
| Max. humidity | 80 %, non-condensing |
| Parameterisation & Display | |
| Parameterisation / Programming | Menu-driven via rotary pushbutton and two function keys Languages: EN, DE, FR, IT, ES, PT, SV, DA, FI, PL, HU, RO, CZ, RU, KO, ZH |
| Display | Daylight-readable TFT colour graphic display Resolution: 240 × 320 pixels Colours: 65,536 |
| Connections | |
| General | Plugged spring-cage terminal block |
| AC power supply | Plugged and screwed spring-cage terminal block |
| Inputs | |
| Analog inputs | 1× 4…20 mA external level (2-wire probe) 1× 4…20 mA external level (2-wire probe, HART) |
| Sensor bus | 1× RxTx bus for NIVUS air-ultrasonic active sensor (OCL) |
| Additional analog inputs | 1× (Type S1/G1), 4× (Type SR/GR) or 7× (Type M3/G3/M9/G9) 0/4…20 mA, 12-bit resolution, accuracy ±0.4 % FS (20 mA), load 91 Ω |
| Digital inputs | 2× (Type S1/G1), 7× (Type SR/GR) or 10× (Type M3/G3/M9/G9) |
| Velocity sensor inputs | 1× (Type S1/G1/SR/GR), 1–3× (Type M3/G3) or 3× (Type M9/G9) POA, CS2, EBM + CSM, iXT or MPX |
| Outputs | |
| Analog outputs | 2× (Type S1/G1) or 4× (Type SR/GR/M3/G3/M9/G9) 0/4…20 mA, load 500 Ω, 12-bit resolution Accuracy: ±0.1 % at 20 °C (±0.4 % at -20…+70 °C) |
| Bistable relay | 1× SPDT (Type S1/G1/SR/GR) 230 V AC / 2 A (cos φ 0.9), min. switching current 100 mA |
| Relays | 1× (Type S1/G1), 4× (Type SR/GR) or 6× (Type M3/G3/M9/G9) SPDT, 230 V AC / 2 A (cos φ 0.9), min. switching current 10 mA |
| Controller & Data | |
| Controller | 1× 3-step controller, quick-close control, adjustable slide valve position on error (Available for Types SR/GR/M3/G3/M9/G9) |
| Data memory | Internal 1.0 GB Approx. 570,000 data sets with timestamps Readout via front USB stick |
| Storage cycle | 30 seconds to 15 minutes |
| Communication | |
| Interfaces | Modbus TCP (LAN/WAN) Modbus RTU via RS485 or RS232 SMTP / FTP / HTTP |
| Cellular communication | 2G / 3G / 4G via built-in radio modem (Only for Types G1 / GR / G3 / G9) |
Why Choose Process Networks?

ISO-Certified Quality
Our ISO 9001:2015 quality management system ensures full traceability across design, installation, calibration and support.

Technical Expertise You Can Reach
When you contact us, you speak directly to an expert — not a call centre.

Trusted Supplier Partnerships
Exclusive access to premium instrumentation from leading global manufacturers in Germany, Japan, the US and across Europe.

Long-Term Support & SLAs
Most customers stay with us for years because we stay with them providing ongoing maintenance, calibration and on-site service.

Proven Field Experience
Thousands of instruments installed and tens of thousands points monitored daily on systems we support.








Speak to a technical expert about this product
Our experts will guide you to the right solution whether you need a single sensor or a site-wide monitoring system.
Office
Process Networks Ltd,
Unit K20 Drinan Enterprise Centre,
Swords, Co. Dublin, K67 NN59
Call
(01) 211 8414
info@processnetworks.ie