F127 Safe area / Intrinsically safe – Differential Flow Computer for liquids

The F127 flow computer has been developed to calculate corrected differential liquid volume at normal conditions. This is calculated by measuring the uncorrected volumetric flow and actual line temperature in both the supply and return line.

F127-DATA-EN-V2607
Datasheet

Measure. Monitor. Repeat.

For better insights, better decision-making and better process performance.

Key Features & Benefits

  • Displays corrected consumption (flow rate), total and accumulated total.
  • Supply line: displays actual temperature and corrected flow rate.
  • Return line: displays actual temperature and corrected flow rate.
  • Analog output signal reflecting the corrected consumption / flow rate.
  • Displays total and flow rate simultaneously and additional accumulated total.
  • Large digit selection for flow rate or total.
  • Flow rate: seven 17mm (0.67″) or 8mm (0.31″) digits.
  • Total – resettable: seven 17mm (0.67″) digits.
  • Accumulated total – not resettable: eleven 8mm (0.31″) digits.
  • Temperature: six 17mm (0.67″) digits.
  • Engineering units for flow rate, total and temperature on the display.
  • LED backlight.
  • Intrinsically safe according ATEX and IECEx.

Typical Applications

  • Net fuel consumption calculation for diesel engines on board of ships or locomotives, generators or burners, corrected for the influence of thermal product expansion.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +70°C (-40°F up to 158°F).

Advantages

  • Robust aluminum or stainless steel 316L field enclosure (IP65, IP67 / NEMA Type4X) .
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available - ATEX and IECEx approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.
Signal Inputs
Flowmeter InputsPulse-type inputs: Reed switch, NAMUR, NPN/PNP pulse, sine wave (coil),
active pulse signal.
Different pulse signal types are allowed for input A and B.
Temperature InputsPT100 – 2-wire or 3-wire PRTD sensor
(0)4 – 20 mA
Signal Outputs
Pulse OutputsFunction: One scaled pulse output according to differential or summed
accumulated total (e.g. one pulse every 3.25 gallons) and one configurable
pulse for negative or decreasing total.
Max. frequency: 500 Hz
Pulse length: Adjustable from 0.001 s to 9.999 s
Type: Two passive NPN transistors, active PNP transistors or isolated
electro-mechanical relays
Alarm OutputsNone
Analog OutputsFunction: Re-transmission of compensated differential flow rate
(consumption), scalable to any range (e.g. 200 L/min to 1200 L/min).
Type: One passive isolated, floating or loop-powered 4–20 mA output or one
active (0)4–20 mA or 0–10 V DC output
Supply
Power SupplyLong-life lithium battery
4–20 mA output loop-powered
8–24 V AC/DC
115–230 V AC
Basic: 8–30 V DC
Sensor Supply3.2 V, 8.2 V, 12 V, 24 V DC
Hazardous Area
Intrinsically SafeATEX:
Gas: II 1 G Ex ia IIB/IIC T4 Ga
Dust: II 1 D Ex ia IIIC T200 / 100 °C Da

IECEx:
Gas: Ex ia IIB/IIC T4 Ga
Dust: Ex ia IIIC T200 / 100 °C Da

Explosion ProofATEX / IECEx:
Gas: II 2 G Ex db IIB + H₂ T5 Gb
Dust: II 2 D Ex tb IIIC T80 °C Db
Communication
CommunicationAll process data and settings can be read and modified via the communication
interface.
Protocol: Modbus RTU
Interface: RS232 / RS485 (2-wire or 4-wire) / TTL
HART communication available with the F018 Flow Rate Monitor / Totalizer

Modbus Communication MODBUS communication with Fluidwell F1xx
Declaration of ConformityEU Declaration of Conformity F1 2019-01
Battery Information SheetMSDS Battery-Information-Sheet (8)
F Series Brochure FSERIES-LEAFLET-EN-V2534 (1)

Why Choose Process Networks?

ISO-Certified Quality

Our ISO 9001:2015 quality management system ensures full traceability across design, installation, calibration and support.

Technical Expertise You Can Reach

When you contact us, you speak directly to an expert — not a call centre.

Trusted Supplier Partnerships

Exclusive access to premium instrumentation from leading global manufacturers in Germany, Japan, the US and across Europe.

Long-Term Support & SLAs

Most customers stay with us for years because we stay with them providing ongoing maintenance, calibration and on-site service.

Proven Field Experience

Thousands of instruments installed and tens of thousands points monitored daily on systems we support.

Speak to a technical expert about this product

Our experts will guide you to the right solution whether you need a single sensor or a site-wide monitoring system.

Office

Process Networks Ltd,
Unit K20 Drinan Enterprise Centre,
Swords, Co. Dublin, K67 NN59

Call

(01) 211 8414

Email

info@processnetworks.ie

    By submitting your enquiry, you agree to receive updates from Process Networks in accordance with our Privacy Policy.