HVT 300-DP
The HVT 300-DP is a SIL2-rated transmitter that measures a differential voltage (up to +/- 250 V DC). Typically, it is used in electrolyser applications to identify leakages in stacks, membrane failures or ground faults. It provides valuable insight of the voltage distribution in the process to the operator, allows to optimize the operation and prevents accidents
Measure. Monitor. Repeat.
For better insights, better decision-making and better process performance.
Key Features & Benefits
- Failsafe voltage monitoring
- Simple software configuration via USB or Modbus RTU – +/- 250V DC measurement range
- Redundant architecture
- Robust design with high dielectric strength
- SIL2 according to IEC/EN 61508
- Two individual safety outputs
- LED status: Power, Error, Alarm
- 10-year proof test interval

Typical Applications
- Monitoring busbar symmetry in hydrogen electrolysis systems
- Optimizing efficiency, safety, and reliability of electrolysis processes
- Ensuring consistent and high-quality hydrogen production
- Proactive detection of cell ruptures, leakages, or insulation faults in Chlorine-Alkali processes
- Preventing current imbalance that can reduce performance or cause safety risks
Scope of use
- Battery Testing
- High power supplies
- Chlorine Alkaline Electrolysis
More info
Safety Features
Featuring a design approach that involves thorough self-monitoring, the HVT 300-DP provides a wide range of diagnostic functions. In order to create a safety loop, the desired output must be evaluated in conjunction with one of the two diagnostic relays REL3/REL4. This way, two individually configurable safety outputs can be created, for which either the relays REL1/REL2 or the 4…20mA analog output are available.
| Parameter | Specification |
|---|---|
| Certificate | SIL 2 according to IEC 61508 |
| Measurement range | ±250 VDC |
| Input resistance | 12 MΩ each channel |
| Analog output | 0/4–20 mA |
| Load | Max. 500 Ω at 22 mA |
| Accuracy | < 0.5% |
| Contact outputs | Normally Open Switching Power: Max. 62.5 VA / Max. 30 W Switching Voltage: Max. 125 VAC / 110 VDC Switching Current: Max. 1 A Contact Material: Ag Pd + 10 µAu |
| Status LEDs | Power: Green Error / SIL Alarm: Red REL1 / REL2: Yellow |
| USB Interface | USB 2.0 |
| RS485 Interface | Half duplex, no scheduling, Baud rate: 9600 bps, Device Address: 1–248 |
| Supply | 24 VDC (20–30 VDC) |
| Power consumption | Max. 1.9 W |
| Temperature | Operating: -10°C…+60°C, Storage/Transport: -20°C…+70°C |
| Permissible humidity | 10%–90% r.H, no condensation |
| Max. operating altitude | < 2000 m above mean sea level |
| Temperature coefficient | Max <0.01 %/K, Typical <0.005 %/K |
| Galvanic isolation / Overvoltage category | 4.3 kV AC test voltage, CAT II: 1000 V, Pollution Degree 2 |
| PCB material | FR4 |
| Housing material | Polyamide |
| Protection class | IP20 |
| Flammability | UL94 V0 |
| Mounting type | 35 mm DIN rail |
Why Choose Process Networks?

ISO-Certified Quality
Our ISO 9001:2015 quality management system ensures full traceability across design, installation, calibration and support.

Technical Expertise You Can Reach
When you contact us, you speak directly to an expert — not a call centre.

Trusted Supplier Partnerships
Exclusive access to premium instrumentation from leading global manufacturers in Germany, Japan, the US and across Europe.

Long-Term Support & SLAs
Most customers stay with us for years because we stay with them providing ongoing maintenance, calibration and on-site service.

Proven Field Experience
Thousands of instruments installed and tens of thousands points monitored daily on systems we support.









Speak to a technical expert about this product
Our experts will guide you to the right solution whether you need a single sensor or a site-wide monitoring system.
Office
Process Networks Ltd,
Unit K20 Drinan Enterprise Centre,
Swords, Co. Dublin, K67 NN59
Call
(01) 211 8414
info@processnetworks.ie